Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)4 Unauthorized material stored in machine room 12/11/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Post Do not use elevator in case of fire @ each landing 11/3/2021
MO Minimum : Elevators (I) - Pits (I)1 Elevator pit must be kept free of Debris. (I)1 11/2/2022
MO Minimum : Elevators (H) - Machine Rooms (H)8 All wiring in Elevator Machine room must be in Metal Conduit/Flex/ Duct. (H)8 11/2/0222
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No records 10/5/2023
MO Minimum : Elevators (H) - Machine Rooms (H)8 All wiring in Machine room must be Metal Conduit. ( New Pone line is exposed). (H)8
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Must make Emergency Phone operable. 8.6.4.15 11/8/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Must make emergency phone operable. 8.6.4.15 11/2/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Phone failed 11/12/2021
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure x Emergency Light/Bell failed 11/5/2019