Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone does not work. 4/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x The emergency phone line must call out and be received by a 24 hour service line. 10/16/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods There shall be maintenance records in the elevator machine room or accessible to the inspector. Shall consist of maintenance task such as callbacks, examinations, test, adjustments, and replacements 10/15/2020
MO Minimum : Elevators (R) - Power Operated Special Purpose Elevators (R)9 x x Must have interlocks on gates. Red tagged elevator.
MO Minimum : Elevators (R) - Power Operated Special Purpose Elevators (R)6 x The current hoistway door interlock does not prevent the door from being opened when the car is away from the landing. The door shall be provided with approved interlocks. 10/16/2020
conversion conversion conversion - red tag x x Repair top floor interlock 9/18/2018
conversion conversion conversion - red tag x x Repair continuois--pressure operation 9/18/2018
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The Current operating certificate shall be posted in the machine room in a non combustible frame 10/15/2020