Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a No No Repair phone 11/18/2019
conversion conversion n/a No No Repair Alarm Bell 11/18/2019
conversion conversion n/a No No Post current state certificate in machine room 11/18/2019
conversion conversion n/a No No Instasil guard on floriscent light in car 11/18/2019
MO Minimum : Elevators (R) - Power Operated Special Purpose Elevators (R)9 No Yes Install mechanical and electrical interlock on gate bottom floor. 1/14/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Car pan safety needs to be non-combustible material. 10/15/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Display updated operating certificate. 10/15/2020
MO Minimum : Elevators (R) - Power Operated Special Purpose Elevators (R)9 Yes Yes Install mechanical and electrical interlock on bottom landing gate. Unit taken out of service until repaired.
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)1 Yes Yes Safeties did not set with full load. 1/14/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)12 (Door open zones) Yes No Door restrictor does not work. 1/14/2021