Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Post current state certificate in themachine room 6/2/2020
conversion conversion n/a Prove handel on top floor hoistway door 6/2/2020
conversion conversion n/a Provide missing access panel to machine space 6/2/2020
conversion conversion n/a Install guard on light in car 6/2/2020
MO Minimum : Elevators (R) - Power Operated Special Purpose Elevators (R)6 x Hoistway doors shall comply with A17.1 1978 Part XV
MO Minimum : Elevators (R) - Power Operated Special Purpose Elevators (R)9 A car door shall be provided at each entrance, at least 7' high. The door or gate shall be provided with interlocks. 6/2/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Maintenance records and electrical prints shall be provided. 6/2/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods Maintenance shall comply with A17.1 2004 6/2/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Car safety pan needs to be non-combustible material. 6/2/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone does not work. 4/23/2020
conversion conversion conversion - reinspect x Repair phone in car 6/6/2019