Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No No A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. 3/13/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No No A code compliant MCP and all the on-site documentation required shall be provided in the machine room. No MCP or documentation present in room. Repeat violation. 3/13/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 3/13/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods Yes No A current tested fire extinguisher is required in the elevator machine room. 7/10/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No A permanent lighting fixture shall provide an illumination of not less than five foot-candles at the pit floor. 3/13/2026
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No A permanent lighting fixture shall provide an illumination of not less than five foot-candles at the pit floor. Repeat violation. 3/13/2026
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No All non-elevator related equipment or materials shall be removed from the machine room. 7/1/2020
MO Minimum : Elevators (I) - Pits (I)1 No No Clean the pit of oil. 3/13/2026
MO Minimum : Elevators (I) - Pits (I)1 No No Clean the pit of oil. Repeat violation. 3/13/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Current ABC type fire extinguisher required in the machine room.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Current operating certificate is required in the machine room.
MO Minimum : Elevators (I) - Pits (I)1 No Yes Fluids are leaking from the jack head/plunger gripper area. Repair as needed. 7/1/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.5 Code Data Plate No No Install a code data plate. It shall read "Missouri Minimum". 3/13/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.5 Code Data Plate No No Install a code data plate. It shall read "Missouri Minimum". Repeat violation. 3/13/2026
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) No No Lighting in the machine room shall be not less than 10 foot candles at floor level. Repeat violation. 3/13/2026
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) No No Lighting in the machine room shall be not less than 10 foot-candles at floor level. 3/13/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Machine room shall have proper fire extinguisher and shall have current monthly/annual test tag. Expired 2019. Repeat violation 3/13/2026
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)2 No Yes Observed a relief pressure of 700 psi. This pressure exceeds last years pressure of 400. Repair and retest the relief pressure. 7/1/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Pipes conveying liquid, gas, or vapor that cross overhead of elevator equipment or come in close proximity of the equipment shall be guarded or guttered. This is in reference to the pipe behind and over the elevator controller. 3/13/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Pipes conveying liquid, gas, or vapor that cross overhead of elevator equipment or come in close proximity of the equipment shall be guarded or guttered. This is in reference to the pipe behind and over the elevator controller. Repeat violation. 3/13/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Provide a current tested fire extinguisher in the machine room. 7/1/2020
MO Minimum : Elevators (I) - Pits (I)8 No No Provide a permanent, non-combustible pit sump pump cover capable of supporting at least 200 lbs. 7/1/2020
MO Minimum : Elevators (A) - Hoistways (A)16 No No Remove abandoned electrical conduit at the rear of the hoistway. 3/13/2026
MO Minimum : Elevators (I) - Pits (I)1 No No Remove fluids from the pit. 7/1/2020
MO Minimum : Elevators (I) - Pits (I)1 Yes No Remove the fluids from the pit. The pit shall be kept dry. 7/10/2020
MO Minimum : Elevators (A) - Hoistways (A)1 No No Replace the missing cotter pit on the door closer rod, 2nd floor. 7/1/2020
MO Minimum : Elevators (H) - Machine Rooms (H)8 No No The disconnect located in the machine space shall be provided with a sign to identify the location of the supply side overcurrent protective device. 3/13/2026
MO Minimum : Elevators (H) - Machine Rooms (H)8 No No The disconnect located in the machine space shall be provided with a sign to identify the location of the supply side overcurrent protective device. Repeat violation. 3/13/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No The fire extinguisher is out of date. 3/13/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No The machine room door shall be self-locking. 7/1/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 Yes No The machine room door shall be self-locking. 7/10/2020
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No The machine room shall be cleaned. 3/13/2026