Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Drive sheave liner is worn out on the middle cable, needs replacement. Recommend replacing all 3 sheave liners 5/6/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Drive sheave liner is worn out on middle cable, needs replacement. Recommend doing all 3 sheave liners 5/6/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts No No Drive sheave liner is worn out on the middle cable, needs replaced. Recommend replacing all 3 sheave liners 5/6/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No There is no fireman’s emergency service phase I instruction signage adjacent to the keyed switch at the primary egress floor, as required.
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.5 No No The elevator pit light did not work on the day of inspection, repair for proper illumination of the pit floor.
A17.1-2016 : Elevators 3.2 - Car top light and outlet 2.14.7.1.4 No No The car top inspection light/fixture did not operate. Repair light/fixture for proper operation and illumination for maintenance/emergency personnel.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Inspection incomplete. Need to perform the following tests: car & counterweight buffers need testing, 125% brake test, full load test of safeties, adjust governor and spin test for proper speeds. Re-inspection required 4/10/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes Yes The SOS switch on the safety plank would not reset after testing the safeties, elevator is shout off until SOS switch is repaired. This test is incomplete, car & counterweight oil buffers need to be tested. Red-tagged, Re-inspection required 4/11/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Need to perform testing of car & counterweight buffers to complete Cat 5 inspection. Re-inspection required 12/15/2025