Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Emergency phone is not working, Re-inspection required 3/25/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 5.3.1.8.3 Clearance between Hoistway Doors and Car Doors or Gates The distance between the hoistway face of the landing door or gate and the car door or gate shall not exceed 100mm (4in.) The top of the door spacer shall be no less than 30 inches from the landing with a beveled top at a 75 degree angle. The clearance shall be reduced or the unit shall be placed out of service per MDFS Deputy Chief Hayes.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 5.3.1.7.2 Clearance between Hostway Doors or Gates and Landing Sills and Car Doors or Gates. The clearance between the face of the hoistway doors and the hoistway edge of the landing sill shall not exceed 9mm (.75 in) and 57mm (2.25 in.) for sliding doors. The clearance shall be reduced or the unit shall be placed out of service per MDFS Deputy Chief Hayes
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 5.3.1.18.3 Key - Operated Switches Hall buttons shall be operated by means of a key switch with the key removable only when switch is in the off position. Keyed switches shall not be of continuous pressure spring return type. The key switch shall be made operable or the unit shall be placed out of service per MDFS Deputy Chief Hayes.