Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Need to provide lighting in machine room to be at least 10 fc at floor
MO Minimum : Elevators (I) - Pits (I)1 Pit has 6" of standing water, needs to be removed. This is a re-occurring issue. Sump pump needs to be installed in pit
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Repair pit light fixture. 9/26/2020
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x x Hoist ropes are rouged & undersized. Unit is Red-tagged, Re-inspection required 7/25/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.6 - Ventilation 2.7.5.2 HVAC unit in machine room is not maintaining manufacturer temperature and humidity recommendations, needs repaired