Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Replace suspension ropes. Reduced diameter 4/5/2018
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)9 Capacity Plate Post elevator capacity tag inside elevator
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Reduced diameter 5/26/2021
A17.1-2016 : Elevators 6.1 - Operation of elevators under fire and other emergency conditions (A17.1b-1973 through A17.1b-1980) 8.6.4.19.6 x 8.6.4.19.6 When the car is placed on phase 1 fire service the elevator should recall and hold at the recall floor. The car remains in normal operation after recalling.
A17.1-2016 : Elevators 1.8 - Door closing force 8.6.4.19.8 x Reduce door closing force to not exceed 30 ft lbs.