Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No emergency phone did not work, phone line dead, no dial tone, provide working phone line 6/2/2023
MO Minimum : Elevators (I) - Pits (I)1 No No clean the pit, water and oil mixture couple of inched deep 3/27/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 2.14.7.1.1 Not less than two lamps No No required to have minium of 2 working lights in the elevator cab, at the time of the inspection only one light was working 7/20/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.11 - Disconnecting Means and Control 2.26.4 No No Machine room space heater cannot be hooked to the line side of the main line disconnect for the elevator, must have separate power for machine room space heater
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.11 - Disconnecting Means and Control 2.26.4 No No Machine room space heater cannot be hooked to the line side of the main line disconnect for the elevator, must have separate power for machine room space heater 3/27/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.1.5 Phase 1 Visual Signal (Re-Inspection) Yes No repair main landing hall button station, fire service indicator jewel is pushed into faceplate 7/16/2025
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.2 Phase I Operation Recall by Initiating Device Yes Yes the fire service initiating devices have all been removed, the smoke detectors all failed because it is a high dust environments 2/23/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.2.1 Phase 1 Emergency Recall OperationBy Fire Alarm initiating Devices Yes Yes fire service initiating devices have all been removed, fire alarm control panel has been turned off, outside elevator smoke detectors won't work, need to use alternate initiating devices to recall the elevator, high dust environment 6/2/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.2.1 Phase 1 Emergency Recall OperationBy Fire Alarm initiating Devices Yes Yes All fire service initiating devices have been removed, fire alarm control panel has been disabled, repair system or apply for variance from state of Missouri 3/27/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.1 No No Junction box in the machine room has bare wires hanging out of it, cap exposed wires and install cover on junction box
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.1 No No Junction box in the machine room has bare wires hanging out of it, cap exposed wires and install cover on junction box 3/27/2026
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage No No No "in case of fire use stairs sign", needed on bottom landing
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone did not have an active phone line, provide working phone line 4/12/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone did not have an active phone line, provide working phone line 7/16/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A copy of the state certificate is to be posted in the machine room
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No emergency phone did not work, phone line was dead 8/21/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.11.2.2.6 Fire Fighters Operation (Re-Inspection) Yes No All fire service initiating devices have been removed, fire alarm control panel has been disabled, repair system or apply for variance from state of Missouri 4/12/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.11.2.2.6 Fire Fighters Operation (Re-Inspection) Yes No All fire service initiating devices have been removed, fire alarm control panel has been disabled, repair system or apply for variance from state of Missouri 7/16/2025
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No All fire service initiating devices have been removed, fire alarm control panel has been disabled, repair system
A17.1-2016 : Elevators 5.11 - Plunger and Cylinder 8.11.3.1.5(c) No No water in the jack head from the last time that the pit flooded needs to be cleaned out. 3/27/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 No No Machine room fire extinguisher is missing, provide fire extinguisher in the machine room
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No machine room fire extinguisher inspection tag is from 2020, needs to be inspected annually. 3/27/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters Emergency Operation: Monthly Testing No No The monthly fire service test log is not being filled out, post a monthly fire service test log in the machine room and fill it out log monthly
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters Emergency Operation: Monthly Testing No No The monthly fire service test log is not being filled out, post a monthly fire service test log in the machine room and fill it out log monthly 3/27/2026
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters’ Emergency Operation Documentation No No monthly fire service test log is not being filled out monthly 3/27/2026
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log No No monthly fire service test log needs to be filled out monthly 3/27/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Emergency Lighting Yes No Emergency lights did not come on, alarm bell worked 4/12/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Emergency Lighting Yes No Emergency lights did not come on, alarm bell worked, replace emergency battery 7/16/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits No No Elevator pit is full of water mixed with oil, water is on the head of the jack, drain the pit, provide means to prevent the accumulation of groundwater in the pit 3/27/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits No No Elevator pit is full of water mixed with oil, water is on the head of the jack, drain the pit, provide means to prevent the accumulation of groundwater in the pit 3/27/2026