MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
B(11)/1.6.1/8.11.2.1.1(f)/8.6.4.15 : 2-way communication device shall work properly (turns off w/o 120v and randomly)
|
11/1/2021
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
B(11)/1.6.1/8.11.2.1.1(f)/8.6.4.15 : 2-way communication device shall work properly (turns off w/o 120v and randomly)
|
11/1/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection)
|
x
|
|
Restrictor shall work at all floors
|
1/23/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting)
|
x
|
|
emergency lite needs battery
|
11/27/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Repair/Replace motor timer, failing contacts.
|
12/3/2021
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Remove dirt and rubbish from pit floor
|
6/9/2024
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
needs current certificate posted
|
11/8/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.1 Replacement Parts
|
|
|
Replace missing Upthrust rollers on hoistway doors.
|
1/24/2023
|
conversion
|
conversion
|
n/a
|
|
|
door restrictor needs repaired
|
11/8/2019
|