MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
Provide a code compliant MCP including onsite documents.
|
6/1/2021
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
x
|
|
8.6.5.17 In the case of a loss of pressure, the plunger gripper needs to be able to stop and hold the elevator with the rated load from traveling in the down direction.
|
3/5/2026
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
This unit is equipped with a plunger gripper that is due for a full load test. A category 5 test shall be performed in 2021.
|
5/11/2021
|