Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records does not have Maintenance Control Program (MCP) documents in the machine room
MO Minimum : Elevators (H) - Machine Rooms (H)6 label pit, cartop, and car operating panel Elevator #1 1/26/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Machine and fire extinguisher inspection tags are expired, Need fire extinguisher with a current inspection tag
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x repair alarm bell push button, the center part of the push button is missing 10/11/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x repair the emergency light system, the lights and bell did not work with the 110 volt power off 7/29/2020
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Replace burnt out machine room lights
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x replace the emergency light battery it is dead 3/12/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.7 Record of Oil Usage The last entry on the oil record log is from 2017 1/26/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records The Maintenance Control Program (MCP) On-Site documents are not in the machine room. 1/26/2022