| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | the whole campus phone system was hit by lightning. They are in the process of repair | 10/5/2023 |
| conversion | conversion | n/a | No | No | Only eleveator related equipment allowed in machine rooom | 7/31/2018 |