MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
2-way communication device shall give proper location message, not able to give proper location (REINSPECTION REQUIRED)
|
8/13/2021
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
2-way communication device shall give proper location message, not able to give proper location (REINSPECTION REQUIRED)
|
8/13/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.1 - Door Re-opening device
|
2.13
|
|
|
2.13.5.1 device stops door from closing on phase II
|
7/2/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.17 - Drive machine brake
|
2.24.8.3
|
x
|
|
2.24.8.3(c) & 2.19.1 cable governor does not actuate off governor switch
|
5/2/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) including Wiring Diagrams, Oil loss log and Fire service testing log, recorded monthly.
|
3/22/2023
|
conversion
|
conversion
|
n/a
|
|
|
emergency light needs battery
|
7/2/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.10 - Hoistway construction
|
2.1
|
|
|
Fire caulk/fill holes and voids in Hoistway walls
|
3/22/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.22 - Wire rope fastening and hitch plate
|
8.6.3
|
x
|
|
Hoist Rope tails are missing clips. Replace as needed.
|
3/22/2023
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
Replace missing interlock cover @2nd floor, exposed wiring
|
7/30/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.8 - Top emergency exit
|
8.11.2.1.3(l)
|
|
|
Top emergency exit shall be secured.
|
3/22/2023
|