Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a pit needs to be dry and clean 3/13/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 Top emergency exit shall be secured properly.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection jack drain tubes shall be routed to a measurable container in the pit. Currently routed straight to tank.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Must post current Stat operating Cert. 5.100(2)
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) .
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit Pit equipment must be cleaned to remove rust and re-painted. 8.6.4.7
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Must provide means to collect and Monitor jack packing gland oil usage. 8.6.5.5.2
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. x Battery Lowering shall work. Repair. REINSPECTION REQUIRED =/> 5/30/22 2/10/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. x Pit shall be kept dry. Standing Water on pit equipment. Clean pit and pit steel for reinspection of C-channels and pipe stands for possible replacement. REINSPECTION REQUIRED =/> 5/30/22 2/10/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Must Make Emergency Phone operable. Reinspection required in 14 days 3/25/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x 1.06 gtelephone does not work 2/25/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Telephone has no dial tone 5/29/2020