Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be obtained and displayed in the elevator machine room. 10/16/2023
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Must post current state operating Cert. in Machine room. 5.100(2)
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Must post current state operating Cert. in Mach room. 5.100(2)
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.36 - Hydraulic Cylinders 8.11.3.1.2(s) x This elevator is equipped with a life jacket. A category 5 test is due on the life jacket. 5/4/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2 On-Site Documentation Must provide and maintain on site MCP (maintenance control program). 2.40
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2 On-Site Documentation Must provide and maintain all required MCP doc. on site. 8.6.1.2.2
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. 10/16/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 The fire extinguisher is expired. An up to date inspection tag shall be installed on the fire extinguisher.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Must provide current test tag on machroom fire extinguisher.
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Must provide current test tag on Machine room Fire Extinguisher. 8.6.1.6.5
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.5.2 Collection of Oil Leakage Must provide means to monitor oil loss. ( currently jack overflow tubes routed back to tank.) 8.6.5.5.2
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.5.2 Collection of Oil Leakage Must provide means to monitor oil loss from jack packing gland. 8.6.5.5.2