MO Minimum : Elevators
|
(S) - Fire Service
|
8.6.11.1 Monthly Test and Log
|
|
|
monthly fire service test log is not being filled out
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.2.1 General Maintenance Requirements Documentation
|
|
|
maintenance control program needs to have instructions for performing the relief valve test
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
the copy of the state operating certificate posted in the machine room expired in 2012, a current copy state operating certificate is to be on display in the elevator machine room
|
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.6.11.1 Monthly Test and Log
|
|
|
monthly fire service tis is to be done monthly and the log is to be filled out in the elevator machine room
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
water in the pit, oil collections buckets have tipped over and the drain hoses are no longer in the buckets, clean the pit and provide means to prevent oil collection buckets from tipping over
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
emergency lights did not come on, replace the emergency light battery
|
7/11/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
one of the emergency light bulbs was not working, replace burnt out light bulb
|
2/11/2022
|
MO Minimum : Elevators
|
(S) - Fire Service
|
(S)1
|
x
|
x
|
the door open button did not work on fire service phase 2 (did not shut off elevator, it is the only elevator in the building)
|
2/11/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
emergency phone did not work, said it didn't have any cell minutes
|
2/6/2023
|
MO Minimum : Elevators
|
(S) - Fire Service
|
(S)1
|
x
|
|
Door close button not owrking on Phase II
|
11/19/2018
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
phone
|
11/19/2018
|