MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting)
|
x
|
|
1) Emergency operation of signaling devices, lighting, communication and ventilation, shall be maintained. Phone not working on power outage.
|
10/4/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection)
|
x
|
|
2) Car-door or gate mechanical and electrical components shall be maintained to ensure safe and proper operation including door restrictors.
|
10/4/2019
|
MO Minimum : Elevators
|
(D) - Brakes
|
(D)2
|
x
|
x
|
3) The brake shall be capable of holding the car at rest with its 125% rated load, for 5-year testing.
|
10/4/2019
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
1) Where an alteration is made to firefighters’ service operation (see 8.7.2.28), tests shall be conducted as specified in 8.10.2.2.6. Ref: 8.10.2.3.2(m)
|
5/25/2021
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Firefighter's Emergency Phase II and smoke/sensors still need to be tested to remove red tag.
|
6/23/2021
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)1
|
x
|
x
|
The elevator car safeties failed to apply when the governor was mechanically set. The elevator was tagged out of service and the power disconnected. The elevator shall be repaired and a re-inspection shall be performed before the elevator is returned to service.
|
6/4/2024
|