ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.11 Periodic Inspection and Test.
|
x
|
|
The elevator had to be red tagged. The annual inspection was completed but the category 5 test still needs to be completed.
|
2/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.11 Periodic Inspection and Test.
|
x
|
|
A category 5 test shall be completed.
|
2/21/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.18 - Traction drive machines
|
8.11.2.1.2(p)
|
x
|
x
|
Unit requires a machine automatic box on motor to keep the car from over-speeding. Elevator Red Tagged.
|
2/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.2 - Car top light and outlet
|
8.11.2.1.3(b)
|
|
|
The car top light works intermittently. Repair as necessary.
|
8/8/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.10 - Hoistway construction
|
8.11.2.1.3(p)
|
|
|
There is a hole in the back wall of the hoistway. Patch the hole.
|
8/8/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.10 - Hoistway construction
|
8.11.2.1.3(p)
|
|
|
Patch the hole in the back of the hoistway wall.
|
8/8/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
8/8/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.1 Replacement Parts
|
|
|
Pull chain is needed to open hall door. The device shall unlock and permit the opening of a hoistway door from a landing irrespective of the position of the car.
|
8/8/2023
|