Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x replace missing hoistway door pick up rollers on the top and bottom landings 2/4/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x phone line is dead, cable modem is not working, provide working phone line 12/19/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates In case of fire don't use elevator signage needed 5/14/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Fire extinguisher out of date 5/14/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Plunger has very noticeable knock around 2nd floor. 5/14/2024
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Lighting below 10 foot candles 5/14/2024
MO Minimum : Elevators (H) - Machine Rooms (H)4 Non elevator equipment stored in machine room 5/14/2024
MO Minimum : Elevators (H) - Machine Rooms (H)2 repair machine room door lock and door jamb, door jamb broke because the door lock would not open all the way 1/23/2020
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform monthly fire service test and post the log in the machine room 1/23/2020
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log monthly fire service test log is not posted in the machine room, perform fire service test monthly and keep a test log in the machine room 1/27/2022
A17.1-2016 : Elevators 2.4 - Machine space 8.11.3.1.2(g) Fire caulk all penetrations in the machine room walls to maintain the fire rating of the room, new holes have been made that were not fire caulked 2/11/2021
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post a new copy of the state operating certificate in the elevator machine room every year 2/11/2021