A17.1-2016: Residential
|
5.3.1 Private Residence Electric Elevators
|
5.3.1.7.2 Clearance Between Hoistway Doors and Landing Sills
|
x
|
|
Clearance between swinging hoistway door to landing sill edge over 3/4 inch.
|
10/4/2022
|
A17.1-2016: Residential
|
5.3.1 Private Residence Electric Elevators
|
5.3.1.7.2 Clearance Between Hoistway Doors and Landing Sills
|
x
|
x
|
Landing door to sill clearance over 3/4 inch.
|
10/17/2022
|
A17.1-2016: Residential
|
5.3.1 Private Residence Electric Elevators
|
5.3.1.7.2 Clearance Between Hoistway Doors and Landing Sills
|
x
|
|
Hoistway door spacer needs 75 degree angle on top.
|
9/4/2024
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)7
|
|
|
Pit needs stop switch
|
12/18/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone working but needs message
|
9/4/2024
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room door must be self-closing and self-locking
|
12/18/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
|
|
MCP needed
|
1/6/2022
|
MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)7
|
x
|
x
|
Slack cable switch not working. Drum continues to turn.
|
10/4/2022
|