Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2
|
|
|
Bottom stop switch cover buzzer not working
|
1/10/2020
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2
|
|
|
Upper left handrail inlet guard needs to be replaced
|
1/10/2020
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2
|
|
|
lower left handrail inlet guard needs to be replaced
|
1/10/2020
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2
|
|
|
Bottom left lower balustrade gap exceeds maximum allowable
|
1/10/2020
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2
|
|
|
Demarcation lights not working
|
1/10/2020
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(B)
|
|
|
Replace damaged lower key up/down switch.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided. MCP shall be present and updated.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.2 Escalator Step-to-Skirt Clearance
|
x
|
|
A17.2 - 7.17 - The step indexing loaded gap shall not be greater than 4.8mm on each side.
|
9/10/2021
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.2 Escalator Step-to-Skirt Clearance
|
x
|
|
8.6.8.3 - The step/skirt performance index shall not exceed .4.
|
9/10/2021
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5.2(i) Demarcation lighting
|
x
|
|
Top & bottom demarcation lamps shall be operational.
|
9/10/2021
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5.2(i) Demarcation lighting
|
x
|
|
Bottom demarcation lamps shall be operational.
|
9/10/2021
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.6.2(i) Step Demarcation
|
x
|
|
The top and bottom demarcation lights shall be operational.
|
10/6/2023
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.2 Escalator Step-to-Skirt Clearance
|
x
|
|
The loaded step gap shall not exceed 4.8mm on either side.
|
10/6/2023
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
The escalator step/skirt performance index shall not exceed .4.
|
10/6/2023
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.11.4.1(e) Lighting (demarcation and step lighting)
|
x
|
|
8.6.11.6.2(i) Step Demarcation - The top and bottom demarcation lights shall be operational. (2nd Notice)
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.2 Escalator Step-to-Skirt Clearance
|
x
|
|
The loaded step gap shall not exceed 4.8 mm on either side. (2nd Notice)
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Performance index shall not exceed 0.4. (2nd Notice)
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.1 Escalator Handrails
|
x
|
|
Handrails will be free of major cracks and pinch points. Replace left handrail.
|
|