Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. x could not complete the 5 year weight test since elevator #2 was Red tagged out of service, complete 5 year weight test once both elevators are back in service 12/12/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x emergency phone hangs up before connecting to operator, repair and retest 4/5/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x emergency light did not com on, alarm bell worked 1/4/2022
A17.1-1996 : Elevators 2.6 - Ventilation 101.5b machine room air conditioning unit does not appear to be keeping the room cool verify proper operation of the air conditioning unit to keep room at the temperatures required by the controller manufacturer 12/20/2023
A17.1-2016 : Elevators 1.4 - Sills and car floor 2.11.10.2 the lobby lights at each landing were not working at the time of the test 6/18/2021
A17.1-1996 : Elevators 2.17 - Drive machine brake 207.2b x x the brake stopped and held but the ropes slid over the dirve sheave and the car went past the down finial onto the buffer 6/18/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post a new copy of the state operating certificate in the machine room every year 4/5/2022
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate in the machine room expired in 2012, update annually with a new copy when received from the state 12/20/2023
A17.1-2016 : Elevators 2.6 - Ventilation 8.11.2.1.2(i) The machine room air conditioner does not seem to be working correctly, the temperature in the room was much higher than the setting on the thermostat 6/18/2021
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(c)(2) A record of findings for firefighters’ service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be kept in the machine room. 6/18/2021
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log monthly fire service test log is to be posted in the machine room 4/5/2022