A17.1-1996 : Elevators
|
3.23 - Suspension rope
|
1001.2(c)(29)
|
x
|
|
The host ropes need to have the tension equalized, one of the ropes has almost no tension on it compaired to the others.
|
3/29/2019
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.4.1(c)(2)
|
|
|
A record of findings for firefighters’ service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be kept in the machine room.
|
6/18/2021
|
A17.1-2016 : Elevators
|
1.4 - Sills and car floor
|
2.11.10.2
|
|
|
the elevator lobby lights at each landing were not working at the time of the inspection.
|
6/18/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
phone dials and then hangs up before operator can answer the phone, repair and retest
|
4/5/2022
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
the state operating certificate in the machine room is to be updated with a new copy every year
|
4/5/2022
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.6.11.1 Monthly Test and Log
|
|
|
there is to be a monthly fire service test log posted in the machine room
|
4/5/2022
|
A17.1-1996 : Elevators
|
3.23 - Suspension rope
|
212
|
x
|
|
hoist ropes are rouged
|
12/12/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.1 Replacement Parts
|
x
|
x
|
replace bad bearing in the machine, elevator red tagged, could not safely complete the 5 year test
|
12/12/2023
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
the state operating certificate in the machine room expired in 2012, update annually with new copy when received from the state
|
12/20/2023
|
A17.1-1996 : Elevators
|
2.6 - Ventilation
|
101.5b
|
|
|
machine room air conditioning unit does not appear to be keeping the room cool, verify proper operation of the air conditioner to keep room at the temperatures recommended by the manufacturer
|
12/20/2023
|