Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a emergecy phone line is dead, provide working phone line 8/9/2019
conversion conversion n/a fire extinguisher inspection tag is from 2015, it is to be inspected annually 8/9/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers machine room fire extinguisher inspection tag is from 2019, it is to be inspected and tagged annually
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers machine room fire extinguisher inspection tag is from 2019, the extinguisher is to be inspected and tagged annually
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) need to have a copy of elevator wiring diagrams in the machine room
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage fire service phase 2 instructions do not match operation, missing instructions for hold and automatic return to recall floor
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log monthly fire service test log is not being filled out
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers machine room fire extinguisher inspection tag is from 2019, the machine room fire extinguisher is to be inspected and tagged annually
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements the top landing shall be illuminated so that when the elevator is in service the lighting shall be not less than 5 foot candles of illumination (110.10b)
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x emergency phone did not work, no phone line, provide a working phone line
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.1 Making Safety Devices Inoperative or Ineffective (Re-Inspection) x the lower landing can not be secured by removing the wiring from both the hall button and the car button, fire service must be able to override security to access the lower landing, currently not able to access the lower landing on fire service
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x emergency phone is not working, phone line is dead 9/9/2022
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x the lower landing can not be secured by removing the button wiring on the car operating panel, the elevator shall be able to go to all landings when the elevator is in fire service operation, use a method to secure the bottom landing that can be overridden by fire service operation. 9/15/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x emergency phone did not work, no dial tone one the phone line, provide a working phone line 9/15/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x phone not working 8/6/2019
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure x the phone line for the emergency phone is dead, provide working phone to the elevator controller 8/18/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x emergency phone did not work, phone line dead 8/20/2021