Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Need to replace pit channels & jack stands in pit 4/25/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit Make way to have sump pump to remove excess water so parts don't rust & fail 4/25/2023
MO Minimum : Elevators (I) - Pits (I)5 Replace pit ladder, its rusted and doesn't touch floor 4/25/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Pit channels and buffer stands are rusted, need replacing 9/1/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Pit ladder is rusted, needs to be replaced 9/1/2023
MO Minimum : Elevators (I) - Pits (I)1 Provide a way to drain excess water in pit to sump pump to prevent further rusting of pit equipment 9/1/2023
MO Minimum : Elevators (I) - Pits (I)8 Provide cover on sump pump hole 9/1/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Fire extinguisher in machine room is expired. Replace or have serviced 9/1/2023
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Need to install phase I fire service instructions at phase I key switch
MO Minimum : Elevators (I) - Pits (I)8 Need to install non-combustible cover over pit sump pump