Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 9/21/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. 9/21/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts The broken door close button shall be repaired and properly marked. 11/22/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone shall work. The phone dials out, but could not establish two-way communication. 9/9/2024
MO Minimum : Elevators (S) - Fire Service (S)1 x x The doors shall not close automatically on phase two fire service. The unit wasn't red tagged because it is the only elevator in the building. Re-inspection required in 14 days. 11/16/2022
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage x Phase 2 fire service shall be operational. 7/20/2020