MO Minimum : Elevators
|
(S) - Fire Service
|
(S)1
|
Yes
|
No
|
Instaal Phase ll hall instruction
|
3/4/2019
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
No
|
No
|
Obatain and display a current state operating certificate in the machine room.
|
8/25/2021
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
No
|
No
|
Obtain and display a current state operating certificate in the machine room.
|
12/17/2024
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
Provide a means of two way communication inside the elevator.
|
8/8/2022
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
No
|
No
|
Reinstall Machine room Door--bldg had a fire
|
2/14/2019
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)5 (Machine Room Lighting)
|
No
|
No
|
Repair the machine room lights as none are working and 2 are required .
|
12/18/2025
|
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)13
|
No
|
No
|
Replace the missing drywall at the top of the hoistway . It is to be completley enclosed to the full height.
|
12/18/2025
|