Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Car Emergency System (Re-Inspection) Yes No REPAIR EMERGENCY LIGHT N THE CAR 8/13/2026
A17.1-2016 : Elevators 6.1 - Operation of elevators under fire and other emergency conditions (A17.1b-1973 through A17.1b-1980) 8.6.11.1 Firefighters’ Emergency Operation No No Perform Monthly Fire Service Test & Document it on Log Sheet in Machine Room
A17.1-2016 : Elevators 1.5 - Car lighting and receptacles 2.14.7 No No Repair Emergency Lights
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post Current State Certificate In the Machine Room
conversion conversion conversion - reinspect Yes No Repair phone in car 3/11/2019
conversion conversion n/a No No Clean pit 9/17/2019
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure No No Emergency light in car not working 9/17/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No Need a maintenance control program on site posted on controller 10/25/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current state operating certificate in machine room 10/25/2021
MO Minimum : Elevators (A) - Hoistways (A)10 No No Need to repair pull chain box top floor 8/13/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current Mo state certificate in machine room 8/13/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance No No Jack is leaking 8/13/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit No No After jack is replaced the pit needs to be cleaned 8/13/2026
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage No No Fire service instructions inside car are unreadable needs to be replaced 8/13/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current state certificate in machine room 8/13/2026
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage No No Provide phase 2 instructions in car 8/13/2026
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log No No PERFORM MONTHLY FIRE SERVICE TEST AND DOCUMENT ON THE LOG POSTED IN THE MACHINE ROOM 8/13/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No POST CURRENT STATE CERTIFICATE IN THE MACHINE ROOM 8/13/2026