Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) Yes No Emergency bell does not operate. 11/2/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) Yes No Emergency light does not operate. 11/2/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)7 No No Door closing force shall be no more than 30 lbs. Door force is presently 38 lbs. 2/17/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No Post emergency evacuation of passengers procedure inside machine room. 2/17/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)7 No No REDUCE DOOR TORQUE BELOW 30lbs 12/9/2025
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage No No INSTALL PHASE 2 SIGNAGE