Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars No No Car top dirty 4/9/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit No No Pit dirty 4/9/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 2.4.2 Yes No Runby less than 6 inches 4/9/2026
conversion conversion conversion - reinspect Yes No Access to the Machine Deck not complete, Elev mod work prohibited the contrator from getting this work done. 8/24/2018
conversion conversion conversion - reinspect Yes No Enclosure of machine room must be completed. 8/24/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 8.6.4.11 Yes No Counterweight Runby is 3 inches minimum shall be 6 inches. Shorten Suspension Ropes must reinspect when work has been completed. 5/23/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency phone not working. Bldg line. 8/21/2025