Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.4.19.6 Yes No During phase 2 fire fighters operation the doors will not hold open. For elevators with power-operated doors, when the car is at a landing, with the doors open, and the “FIRE OPERATION” switch is in the “HOLD” position, the car shall remain at the landing with the doors open. The door close buttons shall be inoperative, and car calls shall not be registered. 6/13/2025
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) Yes No Various broken wires on governnor rope - replace 5/8/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No The escape hatch safety switch plug will not seat back into the outlet without having to disassemble the whole mechanism. Replace the outlet.