Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion conversion - reinspect x Telephone in car doesn't work, Will not activate 3/12/2019
conversion conversion n/a When 110AC is turned off to car, the alarm and emergency light don't work 5/9/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Telephone in car needs to monitored 24 Hrs. Should not call cell phone. (Got "not available" recording) 8/27/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency Light and alarm bell do not work when normal power is removed 3/18/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.11 Runby (Re-Inspection) x Hoist Ropes have stretched beyond maximum allowable amount. The counter weight strikes the bottom buffer before the car actuates the Bottom Final Limit. 3/18/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency Light and alarm bell do not work when normal power is removed 4/3/2024
A17.1-2016 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 8.6.4.11 Runby (Re-Inspect) x Hoist Ropes have stretched, reducing runby beyond maximum allowable amount. 4/3/2024