Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.2 Replacement of Suspension Means (Re-Inspection) Yes Yes Suspension ropes are showing rouge and the diameter has reduced beyond the maximum allowable amount. Replace suspension ropes. 5/14/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) Yes No When a car is outside the unlocking zone, the car doors shall be so arranged that when in the closed position they shall be restricted from opening 5/14/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.2.5 Rope Tension (Re-Inspect) Yes No Replace the broken springs located on the suspension rope shackles and tension the ropes 5/14/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No The anti-rotation cable on the car side suspension shackles is frayed and coming apart. Replace the anti-rotation cable.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No Provide a governor rope data tag
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) Yes No When a car is outside the unlocking zone, the car doors shall be so arranged that when in the closed position they shall be restricted from opening.
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone line does not work 3/25/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Inspection incomplete. Need to test pullout/pull through, set the safeties with a full load, fire service, 110 back up power, counter weight buffer, and emergency phone 5/14/2025
A17.1-2016 : Elevators 2.13 - Governor, Overspeed Switch, and Seal 8.6.4.20.2 Yes Yes The pullout is higher than the pull through of the governor. The safetiies releasing carrier does not pull out when the jaw is fully set. 5/14/2025
A17.1-2016 : Elevators 3.20 - Governor rope 8.7.3.16 Yes No 8.7.2.19 - Provide a Governor rope data tag (2.18.5.3)
conversion conversion n/a No No The elevator machine room cannot be used for storage. Remove the items (old AC units) being stored in the machine room to provide proper room for maintenance to be performed. 7/10/2018
conversion conversion n/a No No The fire extinguisher in the machine room needs to be serviced, the last annual service tag indicates it was serviced in 2016. 7/10/2018