MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
Need to add emergency lighting. Re-inspection required
|
2/14/2023
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)5 (Machine Room Lighting)
|
|
|
Elevator machine room lighting is less than 10 foot candles and shall be repaired to have proper lighting
|
10/14/2022
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
Machine room appears to have a crack in the ceiling and it is leaking causing water to drip next to a light outlet and down onto the floor next to the governor. Repair ceiling and clean floor
|
10/14/2022
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
|
|
Elevator pit light shall be a minimum of 5 foot candles and it does not work. Repair or replace
|
10/14/2022
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)8
|
|
|
Pit sump hole is not covered and shall have proper grating coverage
|
10/14/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting)
|
x
|
|
The in car emergency telephone shall be operational.
|
1/18/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
The elevator has a phase 2 fire service key switch inside the elevator and the elevator appears to not have phase 2 fire service. The key switch shall be removed
|
|