Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No Janitorial equipment stored in machine room
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door must be self-locking
MO Minimum : Elevators (I) - Pits (I)1 No No Pit has water. Sump pump not working.
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door has self-closer but door is tight in jamb and must be pulled shut.
MO Minimum : Elevators (I) - Pits (I)8 No No sump hole cover missing
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.7 Record of Oil Usage Yes Yes car failed set test after relief valve test Oil is seen leaking from cylinder at floor level RED TAG
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency phone not working 11/19/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No no working phone line