Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits Clean pit to remove debris, water, and/or oil and address sources. Install no combustible lid for sump pump hole. Must be flush with pit floor and hold 200 lbs
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.4 Plunger Gripper Testing Need to have 5 year test.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x Phone in elevator cab does not work. 11/19/2019
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Unit stopped operating during testing. Test performed include stop ring pressure test, 15 minute standing test & hoistway testing. All other annual tests need to be performed to complete inspection. Re-inspection required 11/28/2023