Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) replace the emergency light battery, it is dead 3/28/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Repair the top of car inspection station, it would not run in the down direction 2/11/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements replace emergency light battery, it is dead 2/11/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records The Maintenance Control Program (MCP) On-Site documents are not in the machine room. 1/3/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements cortop work light bulb is missing, install a new bulb 1/3/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates the location of the 110 volt breaker for the elevator cab lights is not marked down in the machine room, could not find breaker for the lights 1/3/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers machine room fire extinguisher inspection tag is from 2020, have the fire extinguisher inspected and tagged annually
MO Minimum : Elevators (H) - Machine Rooms (H)8 could not find the 110 volt breaker for the elevator cab lights, could not test emergency lights and alarm on battery power
MO Minimum : Elevators (I) - Pits (I)1 standing water in the pit, maintain a dry pit 1/3/2022
MO Minimum : Elevators (I) - Pits (I)1 the pit shall be kept dry. 11/3/2020
MO Minimum : Elevators (I) - Pits (I)1 maintain dry pit, at the time of the inspection there was standing water in the pit 2/11/2020
MO Minimum : Elevators (S) - Fire Service (S)1 x provide key onsite for the fire service keyswitch, could not test fire service 3/28/2019
MO Minimum : Elevators (S) - Fire Service (S)1 x repair fire service phase 1 keyswitch, it did not recall the elevator 8/6/2019