Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State operating certificate not displayed 10/3/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.7 - Car leveling and anticreep devices 8.11.2.1.3(j) all of the leveling vanes have been hit and are bent causing the elevator to not be level with the landing floor, repair all leveling vanes
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.7 - Car door or gate 8.11.2.1.1(g) replace the vertical sliding car gate astragal, over half of the astragal is missing (8.6.4.13.1(g))
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.7 - Car door or gate 8.11.2.1.1(g) replace the vertical sliding car gate astragal, over half of the astragal is missing, and the safety cord for the reversal is broken and needs to be replaced (8.6.4.13.1(g))
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)4 Elevator no load up 40 fpm and no load down 30 fpm.Crosshead data tag car speed 90fpm. 10/3/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Remove scavenger pump from pit. 10/3/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Pull chain unlocking device covers do not lock shut. 10/3/2023