Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Provide proper pit containers for jack oil collection
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.18 - Restricted opening of car or hoistway doors 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) x door restrictor does not work 9/8/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x alarm bell and telephone do not function 9/8/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.8 - Door closing force 8.11.2.1.1(h) x Dpor pressure exceeds 30 pounds 9/8/2020
A17.1-2016 : Elevators 2.1 - Access to machine space 8.11.3.1.2(b) Repair Door closer 11/19/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.35 - Supply Line and Shutoff Valve 3.19 x 3.19.4.7.5 overspeed valve needs to be tested 9/8/2020
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) No Records 11/19/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.1 x repair greenfield connections on top of elevator 9/8/2020
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 Has speed valve (No Tag)
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.9 - Buffers and emergency terminal speed limiting devices 2.22 x Buffers to be mounted properly
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post Updated Certificate of operation 11/19/2020