Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency Telephone line not active. Must Re-inspect in 14 days. Emergency Alarm bell works.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Elevator Corridor call stations shall have signage which reads In Case of Fire Elevators out of Service at each floor.
MO Minimum : Elevators (H) - Machine Rooms (H)2 Elevator Machine room door shall be self closing and self locking Door Closer is missing and locking system is inadequate.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 2.4.2 x Counterweight runby is less than minimum,Ropes need to be shortened. 12/13/2022
conversion conversion n/a Governor rope very rudged--replace 7/31/2018