Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)2 Alterations x Install alteration code data plate. 1/28/2020
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Need to perform the following tests to complete the inspection: fire service, emergency battery lowering, pressure test & 15 minute standing test. Re-inspection required 3/11/2024