Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 8.11.2.1.5(b) x Counterweight buffer is being compressed 1" when car is at top landing. Shorten suspension ropes to maintian proper counterweight runby. 3/4/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.18 - Traction drive machines 8.11.2.1.2(p) x Traction machine leaking oil onto outboard side of drive sheave. Repair leaking seal. 3/4/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.17 - Drive machine brake 8.11.2.1.2(o) x x Emergency brake is not working due to oil leaking onto braking surface and brake pads. Elevator removed from service until repaired. 3/4/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 8.11.2.1.5(b) x Counterweight buffer is being compressed 1" when car is at top landing. Shorten suspension ropes to maintain proper counterweight runby. 2/23/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.18 - Traction drive machines 8.11.2.1.2(p) x Traction machine leaking oil onto outboard side of drive sheave. Repair leaking seal. 2/23/2022
MO Minimum : Elevators (I) - Pits (I)1 Clean pits
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace missing hoistway door gibs on basement doors
MO Minimum : Elevators (H) - Machine Rooms (H)1 Repair lighting above stairway accessing machine room to provide safe access for workers
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light shall work. Repair same