Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(D)
|
|
|
Replace broken step tread.
|
|
Missouri Minimum : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
A copy of the current state operating certificate shall be on display in the machine room.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.13 Escalator Cleaning
|
|
|
Unit needs complete cleandown
|
|
A17.1-2016 : Elevators
|
9.16 - Ceiling intersection guards
|
8.6.8.9
|
|
|
Replace anti climbing barricade on outer decking between units at lower end
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.14 Escalator Entrance and Egress Ends
|
|
|
Walkoff plate at egress end had missing/broken support braces underneath, need to be replaced
|
|
conversion
|
conversion
|
n/a
|
|
|
Bottom demarcation lights don't work
|
5/1/2019
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.1.4 Maintenance Records
|
|
|
Written maintenance control program shall be provided on-site for each elevator.
|
12/19/2022
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(A)
|
|
x
|
Lower escalator brake torque is only 64 ft lbs. Minimum is 125 ft lbs. Replace escalator brake. Escalator removed from service & red tagged. Re-inspection required before use
|
2/22/2023
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.4 Escalator Combplates
|
|
|
Broken comb plate at the bottom shall be replaced
|
3/29/2024
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.6 Steps
|
x
|
|
Replace broken step tread. Re-inspection required
|
3/29/2024
|
Missouri Minimum : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
A copy of the current operating certificate shall be displayed in the machine room
|
3/29/2024
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.6 Steps
|
x
|
x
|
Most, if not all, step treads have damaged fins on treads, causing sharp edges and excessive gaps between fins. Red-tagged, Re-inspection required
|
10/2/2024
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(A)
|
x
|
x
|
Bottom brake torque is below minimum. Red-tagged, Re-inspection required
|
10/2/2024
|