Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.1.4 Maintenance Records No No Written maintenance control program shall be provided on-site for each elevator. 12/19/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(F) No No Reinstall missing deck barricade at lower landing
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No Step demarcation lights at upper & lower landings do not work, needs repair. 2/22/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.6 Steps Yes No Replace broken step tread 2/22/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(F) No No Re-install missing deck barricade at lower landing
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No Step demarcation lights at upper & lower landings do not work. Re-inspection required 4/10/2025
conversion conversion n/a No No Replace left handrail - Cracks 5/1/2019
conversion conversion n/a No No Top and bpttom demarcation lights don't work 5/1/2019
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No A copy of the current state operating certificate shall be on display in the machine room.