Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (F) - Electrical Switches (F)1 x 1) All electric elevators shall have a labeled emergency stop switch. The switch shall be located on or adjacent to the operating panel. There is no stop switch labeled in elevator. Only a door hold button. This shall be corrected. Ref: (F)1 Re-inspect 1/10/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements x 1) The driving-machine brake shall be maintained to ensure proper operations. When hall door interlock was tripped car continued to move about 2-3 feet. Ref: 8.6.4.6.1 7/29/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x 2) Emergency communications shall be tested to determine conformance with the applicable requirements. Phone was tested several times and there was no response to call. Ref: 8.6.4.19.15 7/29/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements 3) A written Maintenance Control Program shall be in place to maintain the equipment in compliance with the requirements of Section 8.6. Ref: 8.6.1.2.1
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records 1) A written Maintenance Control Program shall be in place to maintain the equipment in compliance with the requirements of Section 8.6. Ref: 8.6.1.2.1
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Car door restrictor is not working. Re-inspection required 8/2/2022
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) 1. Lighting in the machine room shall be not less than ten (10) foot-candles at floor level. The lighting on the upper portion of the machine room, where the machine is located has no lighting. 12/6/2018
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Unit stopped working. 4/20/2022