Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting The cab ceiling is of the open egg-crate type, which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by plastic sleeve or some other means to properly protect passengers. 1/24/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 The elevator machine room door shall be self-closing and shall be operable from the interior space without the use of a key.The closing mechanism has been removed. 1/24/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers There is no fire extinguisher in the machine room, as required. Provide an ABC type extinguisher of proper size for the room. 1/24/2023
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal The fireman's emergency service phase I operation was tested and the following deficiency was noted: The visual or audio signal device did not activate in the car when phase I was activated.
MO Minimum : Elevators (S) - Fire Service (S)1 x x Fire jewel and buzzer are not working on fire recall. Reinspect within 30 days. 1/28/2020
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal x The fireman's emergency service phase I operation was tested and the following deficiency was noted: The visual or audio signal device did not activate in the car when phase I was activated. 12/7/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Repair inoperative emergency phone