Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Car door reopening device is connected to the car lighting circuit 11/24/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Post In Case of Fire signage next to corridor call station at each landing 4/7/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace missing lamps and lens for car direction lantern. 4/7/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.11.1 Firefighters' Emergency Operation & Documentation Test and log firefighter operation monthly 4/7/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace missing lamps and lens on car direction lantern.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No 2022 maintenance record log
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No pit lighting. Repair or replace pit light fixture and/or associated wiring. 11/26/2022
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light does not illuminate 4/7/2022
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Post firefighter instructions on car operating panel 4/7/2022
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Replace illegible firefighter instructions next to hall fire keyswitch 4/7/2022
A17.1-2016 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.14.2 x x Elevator failed set test after annual pressure testing of the hydraulic system. Replace hydraulic cylinder 11/27/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current state operating certificate inside the machine room 4/7/2022