MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)7
|
|
|
Repair or replace GFI in machine room.
|
10/7/2020
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1.1.5 Battery Backup Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone in car not working when 110V is removed.
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
|
Emergency power is existing but was not tested.
|
4/30/2021
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
|
Emergency power is existing but was not tested.
|
3/25/2021
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
|
Firefighters' Service Phase II call cancel button in car not working properly.
|
4/30/2021
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
|
Firefighters' Service Phase II call cancel button in car not working properly.
|
3/25/2021
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)1
|
x
|
x
|
Safeties would not set during Category 1 test. Governor rope pulled through jaw.
|
3/25/2021
|